For critical (choked) flow conditions, which are typical in steam ejectors, the nozzle throat area is calculated using:
This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later.
Section 2: Thermodynamic Constants & Factors (Calculated - Grey) Calculated specific gas constants (
For weeks, the plant’s vacuum system had been underperforming. The steam ejector, meant to pull a vacuum on the main distillation column, was failing to reach its design critical back pressure. Elias had run every CFD simulation in the book, but the real-world results were stubbornly off by 15%. ejector design calculation xls fixed
Steam and gas ejectors are critical components in process industries, valued for their reliability, lack of moving parts, and ability to handle corrosive or hazardous fluids. However, designing a reliable sizing model in Microsoft Excel (XLS) can be incredibly challenging. Engineers frequently encounter bugs, convergence failures, or calculation errors in their custom spreadsheets.
Replace hardcoded constants with a lookup table ( VLOOKUP or XLOOKUP ) linked to the Reynolds number (
If the spreadsheet shows a low entrainment ratio (low efficiency), consider increasing motive pressure or reducing the discharge pressure. For critical (choked) flow conditions, which are typical
Go to File > Options > Formulas → Disable "Enable iterative calculation". This stops the #VALUE! crashes.
At=mmCd⋅Pm⋅kR⋅Tm⋅(2k+1)k+1k−1cap A sub t equals the fraction with numerator m sub m and denominator cap C sub d center dot cap P sub m center dot the square root of the fraction with numerator k and denominator cap R center dot cap T sub m end-fraction center dot open paren the fraction with numerator 2 and denominator k plus 1 end-fraction close paren raised to the the fraction with numerator k plus 1 and denominator k minus 1 end-fraction power end-root end-fraction Cdcap C sub d = Discharge coefficient (typically between 0.95 and 0.98) 3. How to Structure Your Ejector Design XLS Spreadsheet
) and physical dimensions (nozzle throat, diffuser throat diameter). 4. Troubleshooting and Optimization (Fixed Constraints) Can’t copy the link right now
To simplify the ejector design calculation process, an Excel spreadsheet can be used to perform the necessary calculations. A fixed Excel template, often referred to as an "xls fixed" file, can be used as a starting point.
Implement an open-source IAPWS-IF97 steam table add-in for Excel. Replace static
In a fixed spreadsheet, avoid =ITERATION or circular references. Use these direct formulas.
Section 3: Geometry & Sizing Calculations (Output cells - Green) Motive nozzle throat diameter ( Dntcap D sub n t end-sub ) and exit diameter ( Dnecap D sub n e end-sub Diffuser throat diameter ( Ddtcap D sub d t end-sub Estimated total length of the mixing tube and diffuser. Section 4: Performance Curve Generation
Finally, a fixed XLS includes a locked "Report" tab that formats all results (throat diameter, mixing length, predicted backpressure, entrainment ratio) into a single-page summary. No cells in this tab are editable, guaranteeing that printed designs are traceable.